Beckett 7556 12V GeniSys Control Bedienungsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
2
Table 1 - Model Guide
Beckett
GeniSys
12V Control
Part No.
Lockout
Time
Valve-on
delay
time
1
Motor-
off
delay
time
1
7556A 0000
1
15 sec 0 sec 0 sec
7556P 1530
1
15 sec 15 sec 30 sec
7556P 151M
1
15 sec 15 sec 1 min
7556P 152M
1
15 sec 15 sec 2 min
7556P 158M
1
15 sec 15 sec 8 min
1 - Valve-on delay and motor-off delay timings on all models are
programmable with the Beckett Contractor Tool. Other factory
set timings are available. Contact Beckett for alternate timings.
Features
Welded Relay Protection
Limited Relight
Valve-On Delay / Motor-Off Delay (Field
programmable with Beckett’s Contractor
Tool)
15 Second Lockout Time
Interrupted Ignition
Communication Port
Lockout Alarm Output
Speci cations
Electrical Ratings
Inputs:
Voltage: 12 Vdc nominal (11 to 16 Vdc)
Current: 160 mA nominal (500 mA max at
16 Vdc)*
Enable Load: 40mA at 12 Vdc
Outputs:
Motor:
12 Vdc, 20 full load amps (FLA), 100
locked rotor amps (LRA)
Igniter: 12 Vdc, 5 A
Solenoid Valve: 12 Vdc, 2 A
Lockout Alarm: 12 Vdc, 2A
Do Not Use This
Control Above 5.5 GPH
CAUTION
The 7556 control
draws 60-75mA in the
standby state. If the red control wire is left
powered without a battery charging system,
it can drain a standard 45 Amp hour
automotive battery in two to four weeks.
NOTICE
*
Maintain Speci ed
Voltage
A low or erratic power supply could result
in impaired burner operation, severe
delayed ignition or an explosion inside the
heat exchanger resulting in a burn and/or
asphyxiation hazard.
Beckett DC Burners require a continuous
supply of 11 to 16 volts DC (at 15 amps for
Model ADC or 25 amps for Model SDC),
measured at the burner during operation.
Consult other DC burner manufacturers’
speci cations for the correct voltage range.
Special Note: The 7556 Control shuts the
burner down if the input voltage drops to
a sustained level of 10 volts DC, or below.
Operation resumes at a sustained input
voltage of 11 volts DC, or above.
An automotive or small engine charging
system that is capable of supplying the
required continuous voltage/amperage is
recommended with certain road equipment,
such as asphalt hot patchers and similar
applications.
This is especially true while maintaining
nominal load temperatures during idle periods.
WARNING
Do Not Use This
Control in an
Application that is Not Within the Ratings
Listed in This Section. Improper Control
Operation May Result.
CAUTION
Environmental Ratings:
Storage and Operating Ambient
Temperature:
-40°F to +160°F (-40°C to
+71°C)
Moisture: 5 to 95% RH, condensing