1Form 6104 BCF23-R05Potential for Fire, Smoke and Asphyxiation HazardsTo the Homeowner or Equipment Owner:Please read and carefully follow all instruc
10Form 6104 BCF23-R05Figure 6 – Nozzle line assembly in burnerZ2308aMeasure dimension fromfront (flat) face of head toend of air tube, as shown.ZbcdMe
11Form 6104 BCF23-R05Figure 8 – Burner installed in appliance frontDimension CF 1400 CF 2300H 18” 18-1/2”J 10-7/8” 10-1/2”K 13-5/8 15-5/8”Insert burne
12Form 6104 BCF23-R05Models CF1400 and CF2300 are shipped with the pump bypass plug installed.Do not remove the bypass plug from the pump. It is requi
13Form 6104 BCF23-R05Figure 9 – One-pipe oil fl ow with “B” pump300 psig high fire125 to 175 psig low fire2320adc cbmagfphField-installedby-pass loopFi
14Form 6104 BCF23-R05Wire the burner — R7184BInstall the burner and all wiring in accordance with the National Electrical Code and all applicable loca
15Form 6104 BCF23-R05StandbyTrial forTrial forignitionLockoutRecycleRun3 4IgnitioncarryoverMotor-offdelay(postpurge)8675Valve-ondelay21Sequence of ope
16Form 6104 BCF23-R05Start-up checklist – Verify the following before at-tempting to start burner.Combustion air supply and venting have been inspe
17Form 6104 BCF23-R05Table 4a. CF1400 Initial indicator adjustment plate settingsFigure 12 – Adjusting plate initial setting, typicalTable 4b. CF2300
18Form 6104 BCF23-R05Initial air settings The following steps outline the procedure for initially setting the damper. Refer to Figures 13A and 13B an
19Form 6104 BCF23-R05Start the burnerPlease read and understand the manual supplied with this equipment. This equipment must be installed, adjusted an
2Form 6104 BCF23-R05Table of ContentsGeneral Information ...
20Form 6104 BCF23-R05Start burner and vent air from oil lineMove the low-fi re hold switch to the low fi re hold position (to hold burner in low fi re wh
21Form 6104 BCF23-R05Annual ServiceReplace the oil supply line fi lter. The line fi lter cartridge must be replaced to avoid contamination of the fue
22Form 6104 BCF23-R05Replacement Parts For best performance specify genuine Beckett replacement partsItem Part Name Description Part No.1 Timer Nozzle
23Form 6104 BCF23-R05Figure 15 – Adjustable mounting platesModel Flange A Flange B Flange CCF140051312(10.00” DIA.)n/a51629(12.25” DIA.)C
24Form 6104 BCF23-R05LimitedWARRANTYFor Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons wh
3Form 6104 BCF23-R05Before you begin . . .The following resources will give you addional information for your installation. We suggest that you consul
4Form 6104 BCF23-R05Please read all instructions before proceeding. Follow all instructions completely. This equipment must be installed, adjusted and
5Form 6104 BCF23-R05Nozzle pressureThe fuel unit nozzle port pressure is factory set at 300 psig. Some original equipment manufacturer burner applicat
6Form 6104 BCF23-R05Vent system The fl ue gas venting system must be in good condition and must comply with all applicable codes.Verify burner componen
7Form 6104 BCF23-R05Verify air tube The information in this section may be disregarded if the air tube is supplied by the appliance manufacturer.On th
8Form 6104 BCF23-R05This burner is designed for clean, dry installations.Electrical controls are not protected against rain or sprayed water.Keep the
9Form 6104 BCF23-R05Mount air tube to burnerRemove the rear access door from the back of the burner for improved access to the interior.Attach the air